AML M3000 Guia do Utilizador Página 27

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 26
M5000 Portable Data Terminal American Microsystems, Ltd.
27
Comm. Setup
Refer to Communications Setup in the previous section.
Laser/CCD Options
Mode
select one of the following options by using the left or right arrow:
Trigger
a trigger pull activates the laser that remains on until the trigger is released, a valid
decode occurs or a laser/CCD timeout is reached. (default)
Pulse
a trigger pull activates the laser that remains on until a valid decode occurs or a
laser/CCD timeout is reached.
Continuous
a trigger pull activates the laser that remains on while the trigger is pressed or a
valid decode occurs before the
laser/CCD timeout is reached.
Blink
a trigger pull activates the laser that remains on for a period equal to the laser/CCD
timeout after a valid decode occurs. The laser blinks 250ms on and 250ms off. Blink mode does
not operate properly for lasers that employ thermal shutdown.
Timeout
if the laser or CCD does not read a bar code within the designated time period,
the device turns off. Select off or a 1-9 second delay. (If the option is set to off, it overrides this
safety feature.) (The default is a three-second timeout.)
Read Delay
this option sets the delay period between successive reads of the same bar
code. This allows the removal of the bar code from the scan field without multiple reads. Select
one of the following options:
0.0 (no delay) – 9.9 seconds (incremented in tenths of a second)
1.0 second (default)
Other Options
Bar Code ID
transmits the bar code identifier character at the beginning of the bar code
data. A space is included between the ID character and the bar code data. Choose Off or On to
activate this option. Default is set to On.
Duplicate Reads
enables reading the same bar code multiple times. (Default is set to
on.)
Read Verify #
value from 0 to 9 denoting number of rereads of same bar code before
accepting it as valid data. (Default is 0.)
F1—F10 Keys
enables reading of function keys in place of ASCII characters. (Default
is set to on.)
Special Keys
enables reading of special keys in place of ASCII characters. (Default is
set to on.)