American Microsystems, Ltd. M5000 Portable Data Terminal
24
Interleaved 2 of 5 Options
Option Setting Description
Decoder *On Enables/disables reading Interleaved 2 of 5 bar
codes.
Check Digit *None
USS
OPCC
USS Check Digit and OPCC Check Digit are
mutually exclusive (only one option can be selected
at a time). You can toggle left or right arrow key to
select option on M5000 PDT.
Send Check *Off Does not transmit Interleaved 2 of 5 check digit with
bar code data.
Fixed Size *Off Reads fixed length I 2 of 5 bar code bar codes only
matching the lengths specified in the fixed size 1, 2
and 3 options defined below.
Fixed Size 1 (6-60) *6 Sets the first valid fixed length for I 2 of 5. Valid
lengths are 2 to 60 characters, however length must
be an even number. Default fixed length is 6
characters and is disabled when set to 0 characters.
Fixed Size 2 (0-60) *0 Sets the second valid fixed length for I 2 of 5. Default
length is set to 0 characters (the second fixed length
is disabled).
Fixed Size 3 (0-60) *0 Sets the third valid fixed length for I 2 of 5. Default
length is set to 0 characters (the third fixed length is
disabled).
Codabar Options
Option Setting Description
Decoder *On Enables/disables reading Codabar bar codes.
Start/Stop *Off Transmits the Codabar start/stop characters.
CLSI Format *Off A blank after the first, fifth and tenth characters of a
14-character Codabar bar code. Bar code length does
not include the start/stop characters.
CLSI Chk Digit *Off Enables/disables the CLSI check digit. When
enabled, all fourteen digit numeric bar codes must
contain a valid check digit.
Code 128 Options
Option Setting Description
Decoder *On Enables/disables reading Code 128 bar codes.
UCC Verify *Off Check for a valid mod 10 check digit. Mod 10 is not
required on UCC mod 10 bar codes (applies to 20-
digit serial shipping container bar codes).
*Send Mod 10 *On Transmits the mod 10-check digit with the bar code
data.
*Notes default